Datasheet

ams Datasheet Page 13
[v1-08] 2020-Jun-29 Document Feedback
TMF8701 − Detailed Description
Timing
Ranging Acquisition Timing
Figure 14:
Ranging Acquisition Timing
Figure 15:
Ranging Timing Diagram
Min Typ Max Units Comment
Ranging time proximity
and distance mode
combined
16.6 ms Varies with operational mode
Ranging init
(including electrical
calibration)
8ms
Only done on startup and if
temperature changed from last
calibration
Ranging period 209 ms Programmable by the interface