Datasheet
BMM150 Geomagnetic Sensor
Page 37
BST-BMM150-DS001-01 | Revision 1.0 | April 2013 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
The timing specification for I²C of the BMM150 is given in Table 31:
Table 31: I²C timings
7
.
Parameter
Symbol
Condition
Min
Max
Unit
Clock Frequency
f
SCL
400
kHz
SCL Low Period
t
LOW
1.3
s
SCL High Period
t
HIGH
0.6
SDA Setup Time
t
SUDAT
0.1
SDA Hold Time
t
HDDAT
0
Setup Time for a
repeated Start
Condition
t
SUSTA
0.6
Hold Time for a Start
Condition
t
HDSTA
0.6
Setup Time for a Stop
Condition
t
SUSTO
0.6
Time before a new
Transmission can
start
t
BUF
1.3
7
fully compliant to the I
2
C specification”UM10204 I
2
C-bus specification Rev.03 – 19 June 2007”