Data Sheet

MP2636 –3.0A SINGLE CELL SW MODE BATTERY CHARGER WITH PPM AND 3.0A BOOST
MP2636 Rev.1.01 www.MonolithicPower.com 28
9/16/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2015 MPS. All Rights Reserved.
START UP TIME FLOW IN BOOST MODE
Condition: V
IN
= 0V, /Boost is always pulled up to an external constant 5V.
MODE
Boost
SS
V
CC
Band
Gap
V
SYS
V
BATT
2.2V
BOOST
2.9V
V
SYS
>V
BATT
+300mV
0V
0V
5V
Down
Mode
0V
5V
0V
5V
V
CC
follows V
BATT
V
CC
follows V
SYS
1.2ms
Figure 10: Mode Start-up Time Flow in Boost Mode