Introduction
This EMG sensor is launched by DFRobot and OYMotion cooperation, which can reflect muscle and neural activities of human by detecting sEMG.
This sensor integrates filtering circuit and amplified circuit. It amplifies minimal sEMG within ±1.5mV 1000 times and depresses noises (especially power frequency
interference) by differential input and analog filter circuit. The output signal is analogwhich takes 1.5V as the reference voltage. The output voltage range is 0~3.0V. The
signal strength is depends on muscle activities. The output signal waveform indicates the muscle activity and helps to analyse and research the sEMG. Specifically, we can
use Arduino as a controller to detect muscle activities, e.g. check whether the muscle is tense; the muscle strength;etc.
This is an active induction sensor can provide high quality signal collection and it is easy to use. Simple preparations are needed to apply the module to whether static or
dynamic areas. Dry electrode is applied to the module and good quality signal are available even without conductive gel. Compared with disposable conductive gel needed by
medical electrodes, it is more convenient to use and has longer service life. Therefore, it is more suited to common users.
Measurements with an analog EMG sensor are noninvasive, convenient and this can be applied to human-computer interactions. With the development of microcontrollers and
integrated electric circuits, EMG circuits and sensors have not just been applied to traditional medical muscle detection researches but control systems.
The supply voltage range is 3.3~5.5V; The supply current should not be less than 20mA; The ripple current and disturbance
current should be as low as possible. Stabilized DC voltage is recommended.
The effective spectrum range is 20Hz500Hz, and the ADC converter which has higher than 8-bit resolution and 1 KHz
frequency are recommended to take samples and digitized to keep original information.
Placing the metal dry electrode should consistent with the direction of muscle.
The product is not a professional medical device and cannot diagnose and cure disease as an assistant device.
Specification
Signal Transmitter Board
Supply Voltage: +3.3V5.5V
Operating Voltage: +3.0V
Detection Range: +/-1.5mV
Electrode Connector: PJ-342
Module Connector: PH2.0-3P
Output Voltage: 03.0V
Operating Temperature: 050
Size: 22mm*35mm (0.87inch*1.38inch)
Dry Electrode Board
Electrode Connector: PJ-342