- 1.Why can't the power reach the maximum power of the
- 2.No agreement can be detected using two cc lines
- 3.Use the tester to trigger fast charge, it cannot
- 4.Why does the PD protocol trigger, when selecting t
- 5.Why does it keep restarting after entering the PD
- 6.Why is the capacity displayed on the tester differ
- 7.The tester automatically restarts when the fast
- 8.Why does the fast charge protocol automatically
5
8.OK key, function key
9.HID-USB data transmission
figure 1
四、 Technical index
Accuracy: ± (a% (‰) reading + word count)
index
Range
Resolution
Accuracy
Input voltage
4
~
24V
0.1mV
±
(0.2
‰
+2)
Input Current
0~5A
0.1mA
±(0.5‰+2)
input power
0~120W
0.1mW
±(0.5‰+2)
Load Equivalent
Internal Resistance
0
~
9999.9
Ω
0.1m
Ω
±
(0.5
‰
+2)
D + / D- voltage
0~3.3V
0.01V
±(1.0%+2)
Equipment temperature
℃
1
℃
±
(1.2%+3)
℉
1
℉
±
(1.2%+4)
capacity
0~99999mAh
0.0001mAh
for reference
energy used
0~9999.99Wh
0.00001Wh
for reference
Cable internal resistance
0~9999.9Ω
0.0001Ω
for reference
Equipment runtime
999 hours 59 minutes 59 seconds
1 second
5 seconds / hour
Record time
999 hours 59 minutes 59 seconds
1 second
5 seconds / hour