Datasheet

ST7735
V1.7 83 2009-12-04
DISON
Display On/Off
‘1’ = On, “0” = Off
TEON
Tearing effect line on/off
‘1’ = On, “0” = Off
GCSEL2
GCSEL1
GCSEL0
Gamma Curve Selection
“000” = GC0
“001” = GC1
“010” = GC2
“011” = GC3
”100” to “111” = Not defined
TELOM
Tearing effect line mode
‘0
’ = mode1, ‘1’ = mode2
ST4
For Future Use
‘0’
ST3
For Future Use
‘0’
ST2
For Future Use
‘0’
ST1
For Future Use
‘0’
ST0 For Future Use ‘0’
“-“ Don’t care
Default
Status Default Value (ST31 to ST0)
ST[31-24] ST[23-16] ST[15-8] ST[7-0]
Power On Sequence 0000-0000 0110-0001 0000-0000 0000-0000
S/W Reset 0xxx0xx00 0xxx-0001 0000-0000 0000-0000
H/W Reset 0000-0000 0110-0001 0000-0000 0000-0000
Flow Chart
RDDST 09h RDDST 09h
Dummy
Clock
Dummy
Read
Send 2nd
parameter
Send 2nd
parameter
Send 3rd
parameter
Send 3rd
parameter
Send 4th
parameter
Send 4th
parameter
Serial I/F Mode Parallel I/F Mode
Send 5th
parameter
Sendth
parameter
Command
Parameter
Display
Action
Mode
Legend
Sequential
transter