User`s manual

29
2
Hardware Installation
1
2
12
11
LCD/Inverter Settings
X
JP3
JP3 is used to select the power supplied to the LCD panel and to
configure the inverter.
Important:
Before powering-on the system, make sure JP3’s setting
matches the LCD panel’s specification. Selecting the incorrect
voltage will seriously damage the LCD panel.
LCD/Inverter Settings - JP3
5V
3.3V
12V
Panel Power
1-3 On
3-5 On
7-9 On
5V
12V
Inverter On Level
2-4 On
4-6 On
Active Low
Active High
Inverter On/Off Select
8-10 On
10-12 On