Instructions / Assembly
24
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
TROUBLESHOOTING AND REPAIR
Igniter pin and burner are wet Wipe dry with a cloth
Igniter battery is incorrectly inserted Check that battery is correctly inserted
No gas flow Check if gas cylinder is empty.
If yes, replace it.
Regulator is not fully connected
to the tank
Check LP tank connection
Gas flow is obstructed Check hose for bends or kinks
Spiderwebs or insect nest in the
end of burner tube
Clean the end of burner tube
Burner ports are clogged Insert an opened paperclip into each of
the burner ports to clean them. Ensure
the appliance is off and all parts are
cooled before attempting to clean
the burner ports
Igniter pin cracked or broken
Burner will not light
using a match
Flame is obstructed at burner ports
Make sure all the gas burner ports are
free of any lava rocks or debris to allow
the gas toflow freely
Regulator hose is pinched
Check the regulator hose for
bends or kinks
Excess flow safety valve
has been activated
Turn the control knob to "OFF", close the
LP tank valve and disconnect the regulator
From the tank. Turn the control knob to
"HIGH" and wait for 1 minute. Turn the
control knob to "OFF". Reconnect
regulator to LP tank. Open tank valve
slowly. Light appliance as indicated in
"To Light"section.
Appliance emits a lot
of black smoke when
lit
Appliance won't light
Sudden drop
in gas flow
Contact customer service for replacement
Electrode wire is loose or
disconnected
Reconnect wire to the igniter
box located inside the table
base behind the igniter button
Electrode wire is shorting
between valve and igniter pin
Contact customer service for
replacement