PYHJ-V1 FTPLFP-1003 FTPLFP-1004 FIRE PIT TABLE
Item no. Reference Image Qty.
Item no. Reference Image Aa Qty.
Item no. Reference Image Qty.
1 F 2pcs G 1pc H 1pc B 1pc F Aa 8pcs F H G Dd 8pcs B Aa Cc Cc B 7
Item no. Reference Image Qty.
2 C 1pc D 1pc E1 1pc Bb 4pcs Cc 8pcs Dd 12pcs E1 D C Dd Cc Dd 8 Cc Dd Bb
3 M 1pc B F OF M 1 2 Make sure the control knob is in the ”OFF” position. Unscrew the push button cap on the ignition module located on the control panel to access the Battery(R) compartment. The ignition module requires one AAA size Battery(M).
4 X 1pc Ee Y X 1pc Ee 4pcs Ff 6pcs Ee Ff 1 10 Y Ff Ff 2
5 180° I 1pc I I I Place propane gas tank (not included) into the metal stand. Make sure the gas tank sits on the metal stand completely. Turn the pre-assembled wing screw on the outer part of metal stand clockwise to secure the propane gas tank tightly.
6 Turn the cylinder valve on the tank clockwise to close the propane tank. Attach the pre-assembled regulator from the table top(B) to the cylinder valve by turning the regulator coupling nut clockwise. Make sure it is fastened securely and tighten connections by hand only.
7 E2 1pc Z 1pc Aa 4pcs Bb 2pcs Dd 6pcs E2 Aa E2 Z Bb 13 Aa
8 J 1pc J 14
9 A 1pc A 15
10 S 1pc T1 4pcs T2 4pcs V 4pcs W 4pcs S S T2 T1 U 16pcs S S S U S S U V W 16 S U
11 K 1pc K Cover the fire pit with PVC cover(K) when not in use or after the appliance completely cools down. This is to protect it from the elements.
LP (Liquid Propane) Gas Supply Connection •Always confirm that the burner control knob is in the OFF position before connecting the gas supply. •Do not obstruct the flow of combustion air and ventilation air to the appliance. To Connect: 1. Ensure that there is no debris caught in the head of gas cylinder, and the head of regulator valve. 2.
SELECTING A LOCATION Always place this outdoor appliance on a hard, level non-combustible surface such as concrete or rocker stone. Minimum Clearance from Unit to Combustible Materials 48"(121.9cm) from the top; 72" (182.9cm) from all sides and back. Do not locate this appliance under any overhead enclosure. Position the appliance so that you have easy access to the control knob. MIN.CLEARANCE 72lnX42ln(183cmX107.2cm) MIN.CLEARANCE 72lnX42ln(183cmX107.2cm) MIN.CLEARANCE 72lnX42ln(183cmX107.2cm) MIN.
VISUAL CHECK Prior to each use, check the hose and valve for excessive wear or abrasions.
LEAK TEST 1.Perform a leak test in a well ventilated area outside. 2.Make sure any open flames or cigarettes are extinguished. 3.Remove the battery. 4.Ensure the burner control knob is in the “OFF” position. 5.Make a soap solution using 1 part water and 1 part liquid detergent in a bowl. 6.Apply the soapy water solution to all connections. 7.Open LP tank valve. 8.A gas leak will be detected by expanding bubbles originating from the point of the leak. 9.
TO LIGHT TIPS: Before Beginning: ·Read and understand the instructions thoroughly. ·Check and make sure that all parts are present. ·For future reference,save this instruction sheet. 1. Locate the burner control knob and make sure it is in the "OFF" position. 2. Connect propane (LP) cylinder. (See above pages). 3. Open LP tank valve slowly. 4. Push igniter button to create sparks at the electrode and hold. 5. Push and turn burner control knob to the "LOW" position.
TO EXTINGUISH 1. Push and turn burner control knob to the "OFF" position. 2. Close the LP tank valve. 3. Disconnect the regulator from the LP tank to close the gas supply when not in use. 4. Make sure that the unit is completely cooled before touching any of the components or putting on the cover. ROUTINE CARE OFF LOW IGITER-PUSH HIGH 1. Keep your appliance free and clear from combustible materials. 2. Visually inspect burner for obstructions, keep tank enclosure free and clear from debris. 3.
TROUBLESHOOTING AND REPAIR PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Igniter pin and burner are wet Wipe dry with a cloth Igniter pin cracked or broken Contact customer service for replacement Electrode wire is shorting between valve and igniter pin Contact customer service for replacement Igniter battery is incorrectly inserted Check that battery is correctly inserted Appliance won't light Electrode wire is loose or disconnected No gas flow Regulator is not fully connected to the tank Burner wil
TROUBLESHOOTING AND REPAIR PROBLEM Flame blow out POSSIBLE CAUSE CORRECTIVE ACTION High or gusting winds Increase flame to"High" Excess flow safety valve has been activated See"Sudden drop in gas flow" above No gas flow Check if gas cylinder is empty. If yes, replace it. Irregular flame patternorflame does Burner ports are clogged not come outof the entire lengthoftheburner See"Burner will not light using a match" above.