EMERGENCY STOP / SAFETY DOOR LOCK 
This machine is equipped with a Safety Door Lock that locks the door closed from when the cycle is 
started until the cycle is complete. The door lock prevents opening the door for up to 3 minutes if the 
power is interrupted during the cycle. 
The Emergency Stop button pauses the washer and allows the door to be opened during the cycle 
after the Safety Door Lock releases. When the Emergency Stop button is pressed an alarm will 
sound and the display will begin counting down from “3”. If the button is released before 3 seconds 
elapse, the alarm will stop and the cycle will continue normally. If the Emergency Stop is held down 
for 3 seconds, the display will count down to “0” and the washer will begin stopping movement and 
water flow and begin draining water from inside the washer. Though the machine may stop wash 
movement quickly, it may take up to 3 minutes for the door to unlock. During that time the alarm 
will continue to sound. When the alarm stops, the door may be opened. The washer may be 
restarted by closing and latching the door, and pressing the Start button. If the washer was stopped 
more than once before the final extract, the cycle will be cancelled. If the washer was stopped during 
final extract, the cycle will be ended. If the washer is stopped for more than 1 hour, the cycle will be 
terminated. 
SPECIFICATIONS 
MODEL  T900/950 60LB WASHER 
CAPACITY 
CYLINDER SIZE 
ELECTRICAL 
DRIVE SYSTEM 
WASH SPEED 
INTERMEDIATE 
EXTRACT 
FINAL EXTRACT 
MACHINE CONTROL 
WATER INLET 
DRAIN VALVE 
60LBS/9 CUBIC FT. (27.2 kg/255 L) 
30” DIA X 22” DEEP (76.2cm X 55.9cm) 
208-240 VAC, 60 HZ, 1 OR 3 PHASE 
SOFT START REVERSING INVERTER DRIVE 
43 RPM 
375 RPM (60 G’S) 
484 RPM (100 G’S) / 573 RPM (140 G’S) / 685 (200 G’S) 
PROGRAMMABLE COMPUTER WITH 6 STANDARD CYCLES. 
4 SOLENOID OPERATED VALVES 
FLOW RATE: 2 DUAL VALVES (9 GAL/MIN) EACH, 30-120 PSI, 
2 SINGLE VALVES (12 GAL/MIN) EACH, 30-120 PSI 
3” DIAMETER 