User guide
  7
ELECTRICAL 
WARNING 
SHUT OFF POWER AND WATER BEFORE OPENING ANY SERVICE PANELS. 
Dexter  T600  washing  machines  are  intended  to  be  permanently  installed 
appliances.  The machine should be connected to an individual branch circuit 
not shared by lighting or other equipment. The connection should be sheathed 
in liquid-tight flexible conduit, or equivalent, with conductors of the proper 
size and insulation.  No power cord is provided.  Such connections should be 
made  by  a  qualified  electrician,  in  accordance  with  the  wiring  diagram. 
(Suggest minimum wire size of 12 ga.) 
FUSING REQUIREMENTS 
15 Amp Time Delay (Dual Element) Fuse(s) (or equivalent circuit breaker). 
TO MAKE ELECTRICAL CONNECTIONS: 
Remove screw and lift out cover located on upper left of machine (viewed from 
back). 
 Figure 3 - Electrical Power Connections 
If  power  is  208-240-3PH-60HZ 
connect  L1,  L2,  L3  and  ground.  
(If there is a high phase it must 
be connected to L3.) 
If  power  is  208-240-1PH-60HZ 
connect L1, L2 and ground. 
 IMPORTANT  
FOR  SAFETY  AND  PROPER  EQUIPMENT 
OPERATION THE GROUND LUG MUST BE 
CONNECTED TO  A GOOD  EXTERNAL 
GROUND. 