User guide
 18 
For each number in the test, the function will be active when the START button 
is  pushed  and  will  be  inactive when  the  START  button  is  released.    Use  the 
SCROLL UP to move from one function to the next. 
!  Step 1 - Lock the door. 
!  Step 2 - Turn on thermoactuator #1 (lock). 
!  Step 3 - Turn on thermoactuator #2 (unlock). 
!  Step 4 - Close the drain valve. 
!  Step 5 - Turn on the cold water to the tub. 
The pressure switch low level setting can be tested at this point. 
The drain valve is closed and cold water is on for as long as the 
START button is pushed.  When the water level reaches a low level, 
the water valve will turn off and no additional cold water can be 
added.    (The  time  required  to  reach  a  low  water  is  dependent  on 
input water pressure. It may require several minutes.) 
!  Step 6 - Turn on the cold water to the dispenser. 
The pressure switch low level setting can also be tested with this 
step. For details see Step 5. 
!  Step 7 - Turn on the hot water to the tub. 
The pressure switch high level setting of the pressure switch can be 
tested at this point.  The drain valve is closed and hot water on 
for as long as the START button is pushed.  When the water level 
reaches  a  high  level,  the  water  valve  will  turn  off  and  no 
additional hot water can be added.  (The time required to reach a 
high  water is dependent on input water pressure.  It may require 
several minutes.) 
!  Step 8 - Turn on the hot water to the dispenser. 
The pressure switch high level setting can also be tested with this 
step. For details see Step 7. 
!  Step 9 - Forward tumble. 
!  Step 10 - Reverse tumble. 
!  Step 11 - Open drain. 
!  Step 12 - Intermediate spin. 
The I/O interface outputs labeled Reverse and Speed1 will be active 
(the two RED LED=s will light). 
!  Step 13 - Full speed spin. 