User guide
 16 
entered.) 
The Water Level LED lights and the Water Temperature LED are out.  The 
water level for  this  segment is  displayed.    If no change is required, 
then continue to the next instruction.  If a change is required, then use 
the SCROLL UP/SCROLL DOWN buttons to change the water level. {"HI" is a 
high water level and "LO" is a low water level} When the desired water 
level is selected, continue to the next instruction. 
When  the  No  Water  bath  is  selected,  the  water  level  has  no  effect. 
Either water level can be selected. 
9.  Push the green ENTER button. (The water level has now been entered.) 
The  Injection Source LED lights and the Water Level  LED are out.  The 
injection  source  for  this  segment  is  displayed.    If  no  change  is 
required,  then  continue  to  the  next  instruction.    If  a  change  is 
required,  then  use  the  SCROLL  UP/SCROLL  DOWN  buttons  to  change  the 
injection source. See the Injection Source table for proper selection. 
If zero is selected, then no injection source is active for this segment. 
 When  the  desired  injection  source  is  selected,  continue  to  the  next 
instruction. 
When the No Water bath is selected, injection signals are prohibited by 
the  electronic  controller.    The  programmed  injection  source  value  is 
ignored. 
10.  Push  the  green  ENTER  button.    (The  injection  source  has  now  been 
entered.) 
The Spin Time LED lights and the Injection Source LED are out. The spin 
time  for  this  segment  is  displayed.    If  no  change  is  required,  then 
continue to the next instruction. If this value requires changing, then 
use the SCROLL UP/SCROLL DOWN buttons to change the spin time in 1 min. 
increments to the desired value, then continue to the next instruction. 
Settings  range  is  from  0  min.  to  10  min.  except  for  the  Final 
Rinse/Extract  segment  where  the  setting  range  is  1  min.  to  10  min. 
REMINDER: If the spin time is set to zero, there will be no spin at the 
end of the bath. 
11.  Push the green ENTER button. (The extract time has now been entered.) 
Once depressed, the Spin Time LED is out and the editing of one segment 
is complete.  The next sequential cycle segment LED lights, unless the 
segment edited above was the Final Rinse/Extract segment. If the Final 
Rinse/Extract segment is edited, after step eleven, the cycle programming 
is complete and the machine will return to the Programming Mode awaiting 
a cycle select (Step 3). 
To exit the programming mode, depress the red STOP button when one of 
the nine cycle segment LED lights is lit.  The programming changes made 
prior to the program exit are retained and the cycle is updated. 
PROGRAMMING INSTRUCTIONS - ENTERING NEW CYCLE 
The T600 comes from the factory with 29 preset wash cycles programmed into the 