Operator`s manual
ORDER OF PROGRAMMING STEPS:
CYCLE LIGHTS
DISPLAY PROGRAMMING STEP DESCRIPTION OPTIONS/RANGE
OF LIMITS
HOUR METER Displays the hours of the "timer" operation. May be reset to zero
HIGH, MED,
LOW
__ __
LEFT MONEY AUDIT
Number of pulses from the left acceptor (dual coin models).
May be reset to zero.
HIGH, MED,
LOW
__ __ RIGHT MONEY AUDIT Number of pulses from the right acceptor (all models). May be reset to zero.
HIGH
__
TEMPERATURE: HIGH Median operating temperature-High (Regular). 150-190°F / 63-87°C
MEDIUM
__
TEMPERATURE: MEDIUM Median operating temperature-Medium (Permanent Press). 120-170°F / 45-75°C
LOW
__
TEMPERATURE: LOW Median operating temperature- Low (Delicate). 110-150°F / 39-63°C
__ __
LEFT COIN VALUE
Value of coin or token deposited through the left acceptor
(dual coin models) in 1¢ increments.
0 through 9999¢
__ __
RIGHT COIN VALUE
Value of coin or token deposited through the right acceptor
(all models) in 1¢ increments.
0 through 9999¢
__
VEND PRICE
Money required to start the dryer in 1¢ increments.
0 through 9999¢
(0000 causes "Free
Vend")
__ __ __
TIME FOR LEFT COIN
Minutes and seconds awarded for one coin or token
deposited through the left acceptor (dual coin models).
0 through 99:55
(minutes : seconds)
__ __ __
TIME FOR RIGHT COIN
Minutes and seconds awarded for one coin or token
deposited through the right acceptor (all models).
0 through 99:55
(minutes : seconds)
__
TIME OF FREE VEND
Minutes and seconds of “Free” dry (If "Free" dry feature is
used - see vend price above).
0 through 99:55
(minutes : seconds)
HIGH
__ __
COOL-DOWN TIME: HIGH Minutes and seconds of cool-down: High cycle 0 through 10 minutes
MEDIUM
__ __
COOL-DOWN TIME: MEDIUM Minutes and seconds of cool down: Medium cycle. 0 through 10 minutes
LOW
__ __
COOL-DOWN TIME: LOW Minutes and seconds of cool-down: Low cycle. 0 through 10 minutes
TEMPERATURE SCALE Sets Temperature Display to °F or °C F or C
DISPLAY: DECIMAL POINT Displays decimal point in prices. OFF or ON
DISPLAY: SECONDS
Displays time remaining in minutes:00 (OFF) or in
minutes:seconds (ON).
OFF or ON