Manual

16
English
NOTICE: Risk of property damage. NEVER turn water supply off while
pressure washer engine is running or damage to pump will result.
4. Turn water source off.
5. Pull trigger on spray gun to relieve any water pressure in hose or
spray gun.
6. Refer to Storage for proper storage procedures.
MAINTENANCE
WARNING: Risk of burn hazard. When performing maintenance,
you may be exposed to hot surfaces, water pressure or moving parts
that can cause serious injury or death.
WARNING: Risk of fire hazard. Always disconnect, spark plug wire,
let the engine cool and release all water pressure before performing
any maintenance or repair. The engine contains flammable fuel. Do
not smoke or work near open flames while performing maintenance.
To ensure efficient operation and longer life of your pressure washer,
a routine maintenance schedule should be prepared and followed.
If the pressure washer is used in unusual conditions, such as high-
temperatures or dusty conditions, more fre quent maintenance checks
will be required.
Engine
Consult the Engine Owner's Manual for the man u fac tur er's
recommendations for any and all maintenance.
NOTE: The engine drain plug is located at the rear of the unit.
Pump
The pump was filled with oil at the factory. The pump on this unit is
maintenance free and requires no oil. If there is a problem with the
pump contact us at AUST 1800 841 749 / NZ 0800 467 813.
Nozzle Cleaning
If the nozzle becomes clogged with foreign materials, such as dirt,
excessive pressure may develop. If the nozzle becomes partially
clogged or restricted, the pump pressure will pulsate. Clean the nozzle
immediately using the following instructions:
1. Shut off the pressure washer and turn off the water supply.
2. Pull trigger on gun handle to relieve any water pressure.
3. Disconnect the spray wand from the gun.
4. Remove the high pressure nozzle from the spray wand. Remove
any obstructions with nozzle cleaning tool (Y) and back flush with
clean water.
Y
FIG. 20 FIG. 21
5. Direct water supply into spray nozzle to back flush loosened
particles for 30 seconds.