Specification
-22 °F to + 122 °F
(-30 °C to + 50 °C)
-22 °F to + 122 °F
(-30 °C to + 50 °C)
Connector Type
Charging Cable Length
Power Wiring
Required Service Panel
Breaker
AC Power Input Rating
AC Power Output Rating
Safety And Operational Ratings
Indicators
Connector And Electrical
Service Panel GFCI
Fault Indicator per UL No
WiFi LED NO wi LED, but with wi logo in LCD
Status LED
Yes
Safety And Connectivity Feature
Ground Fault Detection
20 mA CCID with auto retry
Open Safety Ground Detection
Continuously monitors presence of safety (green wire) ground connection
Plug-Out Detection
Power terminated per SAE J1772 specications
Local Area Network
2.4GHz WiFi (802.11 a/b/g/n)
Device Storage
Local data storage with capacity of up to 90 days of charging session data
(100 sessions) in case of interrupted network connection
Software Updates
Firmware updated over-the-air (OTA)
Installation
install Software Mobile App (iOS & Android)
Outdoor Installation External GFCI may conict with internal GFCI (CCID).
For hardwired installations, use a non-GFCI circuit breaker.
Maximum 11 kW (240V AC * 48A). Output amperage adjustable via mobile
app to 12A,16A,20A, 24A, 32A, 40A 48A
240V AC 60 Hz single phase @ 12A,16A,20A, 24A, 32A, 40A,48A
25 ft(7.6m)
Station Enclosure Rating
Type 4
EMC Compliance
FCC Part 15 Class B
Storage Temperature
Operating Temperature
Related Humidity ≤95% RH, no water droplet condensation
Altitude ≤1.24 miles (≤2000 m)
Safety and Compliance
UL list; complies with UL2594, UL2231-1, UL2231-2
3 Wire – L1, L2 plus Earth (no neutral)
Dedicated Dual Pole rated for 125% of maximum load
(ex: 50A breaker for 40A output)
External GFCI may conict with internal GFCI (CCID).
For hardwired installations, use a non-GFCI circuit breaker.
SAE J1772 standard compliant
Power Measurement Accuracy
+/- 2.0% from 2% to full scale