Specification
-22 °F to + 122 °F
(-30 °C to + 50 °C)
-22 °F to + 122 °F
(-30 °C to + 50 °C)
Connector Type
Charging Cable Length
Power Wiring
Required Service Panel
Breaker
AC Power Input Rating
AC Power Output Rating
Safety And Operational Ratings
Indicators
Connector And Electrical
Input Cord
Service Panel GFCI
NEMA 6-20, 5-15 adapter
Fault Indicator per UL
Yes
Status LED
Yes
Safety And Connectivity Feature
Ground Fault Detection
20 mA CCID with auto retry
Open Safety Ground Detection
Continuously monitors presence of safety (green wire) ground connection
Plug-Out Detection
Power terminated per SAE J1772 specications
Installation
Outdoor Installation
Insert 6-20 or use 5-15 adapter, plug into the wall socket
Maximum 3.84kW (240V AC * 16A).
120V/ 240V AC 60 Hz single phase @ 12A, 16A
25 ft (745.00 cm/293.31 in)
Station Enclosure Rating
Type 4
EMC Compliance
FCC Part 15 Class B
Storage Temperature
Operating Temperature
Related Humidity
≤95% RH, no water droplet condensation
Altitude
≤1.24 miles (≤2000 m)
Safety and Compliance
UL list; complies with UL2594, UL2231-1, UL2231-2
30.00 cm (11.81 in)
Dedicated Dual Pole rated for 125% of maximum load
(ex: 20A breaker for 16A output)
External GFCI may conict with internal GFCI (CCID).
For hardwired installations, use a non-GFCI circuit breaker.
SAE J1772 standard compliant