Product Manual
14
English
• Usepipethatisthesamesizeastheairtankoutlet.Pipingthat
is too small will restrict the flow of air.
• Ifpipingisover100’(30.5m)long,usethenextlargersize.
• Buryundergroundlinesbelowthefrostlineandavoidpockets
where condensation can gather and freeze. Apply pressure
before underground lines are covered to make sure all pipe
joints are free of leaks.
• A flexible coupling is recommended to be installed between
the globe valve/air discharge outlet and main air distribution
line to allow for vibration.
• A separate regulator is recommended to control the air
pressure. Air pressure from the tank is usually too high for
individual air driven tools.
• DO NOT install lubricators between the tank and any spray
equipment, air tool or accessory requiring oil-free filtered air.
• Drainalltraps,filtersanddirtlegsdaily.
SPR AY
GUN
AIR
TOOL
DRAIN
LEGS
FI LTER /
MOISTURE
TRAP
DIR T
LEGS
DRAIN
VALVES
DRAIN
VALVE
LUBRIC ATOR
REGUL ATOR
GLOBE VALVE /
AIR DISCHARGE
VALVE
MA N DISTRIBUTION AIR L NES
Slope pipe in di rection of air o w
Water condensate ows along
bottom of pipe to drain legs
prevent ng t f rom enter ng feeder
lines
REGUL ATOR
BALL
FI LTER
FLEXIBLE
COUPL NG
DRAIN
VALVE
TYPICAL
COMPRESSED AIR
DISTRIBUTION
SYSTEM
A R FLOW
AIR FLOW
FEEDER LINES SLOPE
WITH AIR FLOW
AIR USAGE
L NES
AIR
COMPRESSOR
FI LTER /
MOISTURE
TRAP
FOR BEST PERFORMANCE
the d stance between the
comp ressor and the
moistu re trap should be as
long as possib e
RISK OF BURSTING A LW AYS USE
ME TAL PIPING AND FITT NGS
DRAIN
VALVES
5 MICRON
FI LTER
01 M CRON
FI LTER
How to Use Your Unit (Fig 3)
How to Stop:
Set the Auto/Off switch to “Off”.
Before Starting
WARNING: Do not operate this unit until you read this instruction