Code Possible Cause Possible Solution
2
Lubrication used.
Abrasive media size too large for nozzle.
Abrasive media too moist and is sticking together.
• An oiler system should not be used with this tool. The oil will mix
with the abrasive and cause a clog.
• Replace nozzle with a nozzle large enough to handle abrasive media
size or use finer media.
• Replace media with dry, fresh media.
3
Bulb is burned out.
Power cord is not plugged in.
Power switch is off.
Outlet is non-functioning.
• Replace light bulb.
• Check that the power cord is properly plugged into a working outlet.
• Turn the red light power switch on.
• Have the electrical outlet serviced by a qualified electrician.
4
Cabinet and viewing window has not been cleaned.
Abrasive has tarnished the viewing window.
Foggy or impaired view during use.
• Clean cabinet and viewing window. Refer to page 14 maintenance
and cleaning.
• Peel off the clear damaged window film and replace with new clean
window film. (Extra film included)
• Make sure shop vacuum is on and connected to cyclone.