SYMPTOM CAUSE FIX
COIL NAILERS
Skipping fasteners; intermittent
feed
Feed piston dry Add
DEWALT pneumatic tool oil in hole in feed piston
cover
Feed piston O-rings cracked/worn Replace O-rings/check bumper and spring.
Lubricate assembly
Check pawl binding Inspect pawl and spring on door. Must work freely
Canister bottom not set correctly Set canister bottom for length of nails being used
Broken weld wires in nail coil Remove coil of nails and use another coil
Fasteners jam in tool/canister Wrong size fasteners for tool Use only recommended fasteners/check canister
bottom adjustment
Broken welded wires in nail coil Remove coil of nails and use another coil