SDS
PRODUCT SAFETY DATA SHEET 
Product Name: Lithium-Ion Battery Packs (less than or equal to 100 Watt Hours) 
Page 3 of 8   Revision 3.1   Issued 12/18/2014 
* * * Section 3 
-
Composition / In
formation on Ingredients * * * 
This battery is an article as defined by 29 CFR 1910.1200 and is not a controlled product under WHMIS. Exposure 
to hazardous ingredients is not anticipated under normal product use. 
Chemical Name  CAS No.  % 
Lithium transition metal oxide (Li[M]
m
[O]
n
)
1
  12190-79-3 
12057-17-9 
182442-95-1 
193214-24-3 
< 30 
Carbon  7440-44-0  < 30 
Polyvinylidene fluoride  24937-79-9  < 10 
Lithium hexafluorophosphate  21324-40-3  < 10 
Ethylene Carbonate  96-49-1  < 10 
Diethyl Carbonate  105-58-8  < 10 
Aluminum foil  7429-90-5  < 10 
Copper foil  7440-50-8  < 20 
Nickel (case)  7440-02-0  < 5 
Steel (case)  65997-19-5  < 10 
Polyethylene (sep.)  9002-88-4  < 10 
Polyimide (ins. tape)  25038-81-7  < 3 
Polysiloxane (adhes.)  68440-63-1  < 2 
Notes: 
1.  The letter ‘M’ stands for transition metal, with potential candidates Co, Mn, Ni, or Al. One compound 
includes one or more of these transition metals and one product may contain one or more of the 
compounds. The letters ‘m’ and ‘n’ represent the number of atoms per unit. 
* * * Section 4 
-
First Aid Measures  * * * 
First Aid: Eyes 
Flush eyes with lukewarm water for at least 30 minutes while holding the eyelids open. Seek immediate 
medical care. 
First Aid: Skin 
Remove contaminated clothing, shoes and leather goods. Flush with water for at least 30 minutes. Seek 
medical attention if symptoms persist. 
First Aid: Ingestion  
Never give anything by mouth if victim is unconscious. Rinse mouth thoroughly water. Do not induce 
vomiting. Seek immediate medical attention.  
First Aid: Inhalation  
Remove person to fresh air away from source of contamination. 
* * * Section 5 
-
Fire Fighting Measures * * * 
General Fire Hazards 
See Section 9 for Flammability Properties. 
Battery cells may rupture when exposed to excessive heat. Electrolyte solution is flammable. 
Hazardous Combustion Products 
May release toxic fumes if burned or exposed to fire. 
Extinguishing Media 
Use appropriate extinguishing agent for surrounding fire. For damaged or ruptured cells, use Class D 
extinguisher or other appropriate agent. Class C fire extinguishers should be used to extinguish electrical 
fires. Do not use water to extinguish electrical or ruptured cell related fires. 
Fire Fighting Equipment/Instructions  
Firefighters should wear full protective gear. 
NFPA Ratings: Health: 0 Fire: 0 Reactivity: 0  