User Manual
4
ENGLISH
WARNING: To reduce the risk of injury, read the
instructionmanual.
Definitions: Safety Guidelines
The definitions below describe the level of severity for each
signal word. Please read the manual and pay attention to
thesesymbols.
DANGER: Indicates an imminently hazardous
situation which, if not avoided, will result in death or
seriousinjury.
WARNING: Indicates a potentially hazardous situation
which, if not avoided, could result in death or
seriousinjury.
CAUTION: Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderateinjury.
NOTICE: Indicates a practice not related to
personal injury which, if not avoided, may result in
propertydamage.
Denotes risk of electricshock.
Denotes risk offire.
EC-Declaration of Conformity
Machinery Directive
54V Right-Angle Drill
DCD470
DeWALT
declares that these products described under
Technical Data are in compliance with:
2006/42/EC, EN60745-1:2009 +A11:2010, EN60745-2-1:2010.
These products also comply with Directive 2014/30/EU and
2011/65/EU. For more information, please contact
DeWALT
at
the following address or refer to the back of themanual.
The undersigned is responsible for compilation of the technical
file and makes this declaration on behalf of
DeWALT
.
Markus Rompel
Vice-President Engineering, PTE-Europe
DeWALT
, Richard-Klinger-Straße 11,
D-65510, Idstein, Germany
09.10.2018
Identify additional safety measures to protect the operator
from the effects of vibration and/or noise such as: maintain
the tool and the accessories, keep the hands warm
(relevant for vibration), organisation of workpatterns.
The vibration and/or noise emission level given in this
information sheet has been measured in accordance with
a standardised test given in EN60745 and may be used to
compare one tool with another. It may be used for a preliminary
assessment ofexposure.
WARNING: The declared vibration and/or noise emission
level represents the main applications of the tool. However
if the tool is used for different applications, with different
accessories or poorly maintained, the vibration and/or
noise emission may differ. This may significantly increase
the exposure level over the total workingperiod.
An estimation of the level of exposure to vibration and/or
noise should also take into account the times when the tool
is switched off or when it is running but not actually doing
the job. This may significantly reduce the exposure level
over the total workingperiod.
DCD470
Voltage V
DC
54
Type 1
Battery type Li-Ion
Max. Power Output W 2600
No Load Speed
1st Gear min
-1
0–400
2nd Gear min
-1
0–1320
Max torque (Hard/Soft) Nm 269/114
Chuck capacity mm 13
Max Capacity
Wood mm 158
Weight (without battery pack) kg 7.0
Noise values and vibration values (triax vector sum) according to EN60745-2-1:
L
PA
(emission sound pressure level) dB(A) 86
L
WA
(sound power level) dB(A) 97
K (uncertainty for the given sound level) dB(A) 3
Drilling into metal
Vibration emission value a
h,M
= m/s
2
3.5
Uncertainty K = m/s
2
1.5
Drilling into concrete
Vibration emission value a
h,DD
= m/s
2
3.6
Uncertainty K = m/s
2
1.5
English (original instructions)
Congratulations!
You have chosen a
DeWALT
tool. Years of experience, thorough
product development and innovation make
DeWALT
one of the
most reliable partners for professional power toolusers.
Technical Data
54V RIGHTANGLE DRILL
DCD470