Information
DEWALT - LITHIUM CELLS OR BATTERIES TEST SUMMARY
IN ACCORDANCE WITH SUB-SECTION 38.3 OF UN MANUAL OF TESTS AND CRITERIA
Page 1 of 4 Revision 1.4 Issued 12/7/2020
Product Manufacturer: Stanley Black & Decker, Inc.
1000 Stanley Drive
New Britain, CT 06053
Telephone: 1-860-225-5111 Emergency: 1-888-698-2571
Email: SBDbatteries@sbdinc.com
Web: www.stanleyblackanddecker.com
Stanley Black & Decker’s product lithium ion cell and batteries have been successfully tested and comply
with the UN Model Regulations, Manual of Test and Criteria, Part III, subsection 38.3.
Performed Tests
Results
38.3.4.1 T1
Altitude Simulation
Pass
38.3.4.2 T2
Thermal Test
Pass
38.3.4.3 T3
Vibration
Pass
38.3.4.4 T4
Shock
Pass
38.3.4.5 T5
External Short Circuit
Pass
38.3.4.6 T6
Impact/Crush
N/A to battery packs
38.3.4.7 T7
Overcharge
Pass*
38.3.4.8 T8
Forced Discharge
N/A to battery packs
The UN38.3 tests were performed by one of the following test houses and were tested to UN Manual
Test and Criteria Revision 3 Amendment 1 or subsequent revisions or amendments.
*Stanley Black & Decker chooses to perform the Overcharge Test of T7 to demonstrate an extra level of safety. Because our
battery packs are designed to be charged only with Stanley Black & Decker battery chargers, they will never be exposed to the
conditions prescribed in the Overcharge Test.
Shanghai Research Institute of Chemical Industry
Testing Centre
2779 Guangfu West Road, Putuo District,
Shanghai, China 200062
E: center@ghs.cn
T: 021-31765555
U: http://www.ghs.cn/
Vkan Certification & Testing Co., Ltd.
No.3,Tiantaiyi Road, Kaitai Avenue, Science City,
Guangzhou P.R. China 510663
E: office@cvc.org.cn
T: 020-32293888
U: http://www.cvc.org.cn
Product Test Information
Model Number
Physical
Description
Battery
Weight
(kg)
Battery
Voltage
(V)
Wh
Rating
(Wh)
Test report Number
Test Report
Date
DCB080
Removable
Battery Pack
0.08
8/7.2
8.0/7.2
E1209175
9-3-2012
DCB120/DCB125
Removable
Battery Pack
0.22
12/10.8
15.6/14
18/16.2
1113070017
1113120004
8-12-2013
4-15-2014