An extension cord must have adequate wire size
(AWG or American Wire Gauge) for safety. The smaller
the gauge number of the wire, the greater the capacity
of the cable, that is, 16 gauge has more capacity than 18
gauge. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. When using
more than one extension to make up the total length,
be sure each individual extension contains at least the
minimum wire size. The following table shows the correct
size to use depending on cord length and nameplate
ampere rating. If in doubt, use the next heavier gauge. The
lower the gauge number, the heavier thecord.
Minimum Gauge for Cord Sets
Volts
Total Length of Cord in Feet
(meters)
120 V 25 (7.6) 50 (15.2) 100 (30.5) 150 (45.7)
240 V 50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
Ampere Rating
American Wire Gauge
More
Than
Not
More
Than
0 6 18 16 16 14
6 10 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not Recommended
The label on your tool may include the following symbols. The
symbols and their definitions are asfollows:
V ......................... volts
Hz .......................hertz
min ..................... minutes
or DC ......direct current
...................... Class I Construction
(grounded)
…/min ..............per minute
BPM .................... beats per minute
IPM ..................... impacts per minute
RPM .................... revolutions per
minute
sfpm ................... surface feet per
minute
SPM .................... strokes per minute
A ......................... amperes
W ........................watts
or AC ...........alternating current
or AC/DC .... alternating or
direct current
...................... Class II
Construction
(double insulated)
n
o
.......................no load speed
n .........................rated speed
......................earthing terminal
.....................safety alert symbol
.....................visible radiation
..................... wear respiratory
protection
..................... wear eye
protection
..................... wear hearing
protection
..................... read all
documentation
SAVE THESE INSTRUCTIONS FOR
FUTURE USE
Motor
Be sure your power supply agrees with the nameplate
marking. Voltage decrease of more than 10% will cause loss
of power and overheating.
DeWALT
tools are factory tested;
if this tool does not operate, check powersupply.
SPECIFICATIONS
D25872 D25892
Rated Size
19.4 lbs.
(8.8 kg)
22 lbs. (10 kg)
Tool Holder SDS MAX SDS MAX
Amps 15 A 15 A
Impact Energy in Joules (EPTA) 13.3 J 19.4 J
No-Load BPM 1350–2705 1105–2210
Weight
19.4 lbs.
(8.8 kg)
22 lbs. (10 kg)
Length 21.4" (54.3 cm) 23.3" (59 cm)
Width 4.5" (11.3 cm) 4.5" (11.3 cm)
Height 11.5" (29.2 cm) 11.5" (29.2 cm)
Vibration Control Yes Yes
Variable Speed Dial Yes Yes
Variable Speed Dial Positions 7 7
Dust Extraction Model # DWH053 DWH053
Noise Values [dB(A)]
L
pA
(Emission Sound Pressure Level) 95 96
L
WA
(Sound Power Level) 106 107
K (Uncertainty of Given Sound Level) 3 3
Vibration Values (m/s
2
)
Chipping/Chiselling (Value a
h,Cheq
) 9.7 13.5
Uncertainty K 1.5 1.5
COMPONENTS (FIG. A)
WARNING: Never modify the power tool or any part
of it. Damage or personal injury couldresult.
Refer to Figure A at the beginning of this manual for a
complete list ofcomponents.
Intended Use
Your heavy-duty chipping hammer is designed for
professional concrete chiselingapplications.
DO NOT use under wet conditions or in presence of
flammable liquids orgases.
Your heavy-duty chipping hammer is a professional
powertool.
DO NOT let children come into contact with the tool.
Supervision is required when inexperienced operators use
thistool.
ASSEMBLY AND ADJUSTMENTS
WARNING: To reduce the risk of serious personal
injury, turn unit off and disconnect it from
power source before making any adjustments or
removing/installing attachments or accessories.
An accidental start-up can causeinjury.