Operation Manual

10
Based on the template on the lower housing component of the magnet, drill holes into the
window frame or door frame and then attach the lower component of the magnet using screws.
Position the magnet in the middle, at a distance < 2 cm from the sensor.
The notches on the magnet and of the sensor should line up with one another.
To close the sensor housing, first insert the lower end of the upper housing component of the
sensor into the corresponding groove in the lower housing component of the sensor and
then press the entire upper housing component, (from bottom to top,
and ) onto the
lower component until it clicks into place.
To close the magnet housing, insert the upper housing component of the magnet until it clicks
into place onto the lower housing component of the magnet. This completes the installation of
the Home Control Door/Window Contact.
From now on, you can take electronic control conveniently using the Home Control portal of the
Home Control Central Unit.
For more information on how to control and configure all devolo Home Control devices, as well as
for application examples, please refer to the Home Control online help.