Specifications

14 Installation
devolo dLAN 200 AVpro DINrail
The device should be located only where sufficient
ventilation can be ensured.
Never use the device with a power supply that
does not meet the specifications provided on the
rating plate.
In the event of damage, contact customer service.
This applies, for example, if
liquid has been spilled on the device or
objects have fallen into the device.
the device has been exposed to rain or water.
the device does not work, even though the
operating instructions have been followed
properly.
the device’s case is damaged.
3.2 Electrical installation
1 Install the dLAN 200 AVpro DINrail properly on
the top-hat rail.
Take into account the vertical in-
stallation alignment of the device,
so that the mains power supply
comes from above.
2 Now connect the conductors according to the line
connections.
When connecting to the sockets,
make sure the conductor cross-sec-
tion is 0.18 mm² to 6 mm².
Single-phase connection: Neutral conductors
and external conductors are connected to ter-
minals N and L1 (see Fig. 4).
Three-phase connection: Neutral conductors
and external conductors are connected to ter-
minals N and L1. The connection of external
conductors L2 and L3 is optional and
intended for optimising the signal transmis-
sion. The device is supplied with power via
terminals N and L1 (see Fig. 5).