Specifications
14 Installation
devolo dLAN 200 AVpro DINrail
쎲 The device should be located only where sufficient
ventilation can be ensured.
쎲 Never use the device with a power supply that
does not meet the specifications provided on the
rating plate.
쎲 In the event of damage, contact customer service.
This applies, for example, if
쑗 liquid has been spilled on the device or
objects have fallen into the device.
쑗 the device has been exposed to rain or water.
쑗 the device does not work, even though the
operating instructions have been followed
properly.
쑗 the device’s case is damaged.
3.2 Electrical installation
1 Install the dLAN 200 AVpro DINrail properly on
the top-hat rail.
Take into account the vertical in-
stallation alignment of the device,
so that the mains power supply
comes from above.
2 Now connect the conductors according to the line
connections.
When connecting to the sockets,
make sure the conductor cross-sec-
tion is 0.18 mm² to 6 mm².
쑗 Single-phase connection: Neutral conductors
and external conductors are connected to ter-
minals N and L1 (see Fig. 4).
쑗 Three-phase connection: Neutral conductors
and external conductors are connected to ter-
minals N and L1. The connection of external
conductors L2 and L3 is optional and
intended for optimising the signal transmis-
sion. The device is supplied with power via
terminals N and L1 (see Fig. 5).