Specifications

dLAN 200 AVmodule 6400
13
devolo AG
Charlottenburger Allee 60 Tel.: +49 (0)241-182 79 0 www.devolo.com
D-52068 Aachen Fax: +49 (0)241-182 79 999 info@devolo.com
7 dLAN 200 AVmodule 6400
Specifications
7.1 Power Supply Requirements
The dLAN 200 AVmodule 6400 needs 1.05V,
3.3V and 11V for operation. The typical power
consumption is 2.5W. Power may be supplied
from the following two possible sources:
1.) Existing Host Power Supply with similar
voltage requirements
2.) Off line Switch Mode Power Supply
Min Typ Max
V
CC
Supply Voltage
1.00 V
1.05 V
1.10 V
V
CC
Supply Current
600mA
800mA
V
DD
Supply Voltage
3.13 V
3.30 V
3.47 V
V
DD
Supply Current
200mA
300mA
V
AA
Supply Voltage
10.5 V
11.0 V
11.5 V
V
AA
Supply Current 80 mA
80 mA
130
mA
Table 13: Power supply requirements
7.2 Power Sequencing Requirements
Do not apply the analog power supply voltage
(VAA) without the 3.3 V (VDD) power supply
voltage!
There are no special requirements between
V
CC
and V
DD
. Both may be applied in any
sequence during power up and removed in any
order during power down versus each other.
7.3 Reset Signal Requirements
The reset signal has to be driven low for at
least 100 ms after all supply voltages are
stable.
Fig. 8: Reset timing – t
RSTa
= 100 ms min.
7.4 Absolute Maximum Ratings
Operation at or above the absolute maximum
ratings may cause permanent damage to the
device. Exposure to these conditions for
extended periods of time may affect long-term
device reliability. Correct functional behavior is
not implied or guaranteed when operating at or
above the Absolute maximum ratings.
Symbol
Parameter Min Max
V
CC
Core Supply Voltage -0.3 V
1.2 V
V
IO
I/O Voltage V
SS
-0.3 V
V
DD
+0.3 V
V
DD
Power Supply Voltage
-0.3 V
3.6 V
V
AA
Analog Voltage -0.3 V
12.5 V
T
STORE
Storage Temperature -40 °C
125
°C
T
OPERATE
Operation Temperature
C 60°C
V
ESD
Electrostatic Discharge
1000
V
Table 14: Absolute maximum ratings