User`s manual

User’s Manual Version 1.2
Devolinx Serial-Ethernet Server
STE-601C
Copyright © 2007 Aaxeon Technologies, Inc.
All rights reserved.
- 47 -
Appendix C. Hardware Configuration
C.1 Disable System Firmware
The AP (application program) firmware of STE-601C can be disabled. This function is used in the situation
that you downloaded a wrong version of firmware that caused the system crashed.
To disable the current version of firmware and prevent it from executing, please do the followings:
1. Turn the power off, open STE-601C case.
2. Short pin1 and pin2 of jumper JP1 on the right-top corner from the main board to disable AP firmware.
3. Power on STE-601C.
4. Download the correct AP firmware to STE-601C.
5. Remove the pin 1 and pin2 of jumper JP1 to enable AP firmware.
6. Close the case and continue your operations.