Athalon
®
CM & Crixus™ User Manual
Seal Material
Fluorocarbon
Filtration Rating
ß>2000 (In to out flow path)
Element Media Option
AZ (3 µm(c)), AP (5 µm(c)), AN (7 µm(c)), AS (12 µm(c))
and AT (25 µm(c)). (µm(c) where Beta =2000)
Flow
R310 to 760 l/min (200 US gpm)
Process Fluid Temperature
-25 – 90°C (-13 – 194°F)
Ambient Temperature
-25 – 60°C (-13 – 140°F)
Maximum Working Pressure
41 bar (600 psi
Rated Fatigue Pressure
41 bar (600 psi)
Filter Element Presence
Detect that the Filter Element is Installed (via RFID)
Filter Element P/N and Grade
Read from RFID tag on Filter Element
Filter Element Runtime
Data Stored on RFID Tag
Filter Element Lot Number
Data Stored on RFID Tag
Filter Element Activation Date
Data Stored on RFID Tag
Filter Element Hours in Service
Data Stored on RFID Tag
Filter Element Machine ID
Data Stored on RFID Tag
Filter Element dP Max
Data Stored on RFID Tag
Filter Element Temperature
Max
Data Stored on RFID Tag
Power requirement.
24VDC, 100mA
Ingress Rating Electronics
IP65 Minimum
Compatibility
Compatible with all petroleum oils and synthetic hydraulic
and lubrication fluids.
2. Installation & Setup
2.1. Filter Node Installation
2.2. Providing a WiFi Access Point
The customer site must provide a WiFi access point (2.4 GHz Wi-Fi 802.11 a/b/g/n) that is
in range of the gateway.
If a WiFi access point is not available, but a wired/Ethernet connection is available at the
customer’s site, Pall recommends one of Cisco’s Meraki wireless LANs, such as the MR18
(https://meraki.cisco.com/products/wireless/mr18) indoor access point.