User's Manual

16
Athalon
®
CM & Crixus User Manual
Port Options H310
Split Flange To ISO6162 (Metric) 1” or 1 ¼”
Side Manifold Mount. 1 ¼” Only
Top Manifold Mount. 1 ¼” Only
O-Ring Boss Per SAE J1926. 1 ¼”, 1 ½” or 2”
BSP Thread To ISO228. 1 ¼”, 1 ½” or 2”
Split Flange To SAE J518 Code 61. 1 ¼”, 1 ½” or 2”
Split Flange To SAE J518 Code 62. 1 ¼”, 1 ½” or 2”
Split Flange To ISO6162 (Metric). 1 ¼”, 1 ½” or 2”
Side Manifold Mount. 1 ¼”, 1 ½” or 2”
Top Manifold Mount. 1 ½” Only
Differential Pressure
1, 2 or 4 bard, 25% Dead band
Seal Material
Fluorocarbon
Filtration Rating
ß>2000 (In to out flow path)
Element Media Option
AZ (3 µm(c)), AP (5 µm(c)), AN (7 µm(c)), AS (12 µm(c))
and AT (25 µm(c)). (µm(c) where Beta =2000)
Flow
UH210 to 230 l/min (60 US gpm)
UH310 to 600 l/min (160 US gpm)
Process Fluid Temperature
-25 90°C (-13 194°F)
Ambient Temperature
-25 60°C (-13 140°F)
Maximum Working Pressure
400 bar (6000 psi)
Rated Fatigue Pressure
240 bar (3500 psi)
Filter Element P/N and Grade
Read from RFID tag on Filter Element
Filter Element Runtime
Data Stored on RFID Tag
Filter Element Lot Number
Data Stored on RFID Tag
Filter Element Activation Date
Data Stored on RFID Tag
Filter Element Hours in Service
Data Stored on RFID Tag
Filter Element Machine ID
Data Stored on RFID Tag
Filter Element dP Max
Data Stored on RFID Tag
Filter Element Temperature Max
Data Stored on RFID Tag
Ingress Rating Electronics
IP65 Minimum
Compatibility
Compatible with all petroleum oils and synthetic hydraulic
and lubrication fluids.
1.2.4.7.2. Athalon R310 Filter Housings
Functional Description
R310 Housing
Port Options R310
Differential Pressure