Technical Specifications refer to data sheet for Pall Part No. RCA222.
1.2.4.7. Athalon Housing Specifications
1.2.4.7.1. Athalon H210 or H310 Filter Housings
Functional Description
Specification/Range
H310 / H210 Housing
Port Options H210
O-Ring Boss Per SAE J1926. 1” or 1 ¼”
BSP Thread To ISO228. 1” or 1 ¼”
Split Flange To SAE J518. 1” or 1 ¼”
Split Flange To SAE J518 Code 62. 1” or 1 ¼”
Differential Pressure Transducer
Seal Material
Viton Fluorocarbon
Housing Material
Brass
Port Options
¾”-16 UNF Thread To BS1580
To Fit housing Pall DPI Port.
Maximum Working Pressure
450 bar (6500 psi)
Proof Pressure
675 bar (9800 psi)
Burst Pressure (Typical)
1100 bar (15900 psi)
Rated Fatigue Pressure
0-400-0 bar (5800 psi)
Process Fluid Temperature
-25 90°C (-13 194°F)
Ambient Temperature
-40 60°C (-40 140°F)
Measurement Differential
Pressure Option
0.25 1.0 bar (3.6 14.5 psi)
1.0 4.0 bar (14.5 - 58 psi)
2.0 8.0 bar ((29 - 116 psi)
Pressure Dead Band
25% Full Scale (As Shown Above)
Temp. Measurement Range
0 100°C (-32 212°F)
Compatibility
Petroleum oils and synthetic hydraulic and lubrication fluids.
Ingress Rating Electronics
IP 65 to IEC 60529 when assembled