User's Manual
11
Athalon
®
CM & Crixus™ User Manual
The Water Sensor is used to measure the dissolved water content in the hydraulic
fluid. This sensor connects to the ‘Water Sensor’ port where indicated on the port
label and using the M8 to 8-pin, M12 connector cable.
Technical Specifications refer to data sheet for Pall Water Sensor (WS12/WS13 Series).
1.2.3. Sensor Manifold
1.2.3.1. Description
The sensor manifold is an optional fitting that can be plumbed into a hydraulic
system and is used to install the Fluid Properties Sensor and the Water Sensor.
WS12 Water in oil sensor (Water content in oil %RH or PPM and Temperature °C or °F)
Seal Material
Viton Fluorocarbon
Housing Material
Stainless Steel
Port Options
½” NPT Internal Pipe Thread to ANSI B2.1
½” BSP (G) to ISO228 To Fit Port 3 Manifold
Maximum Working Pressure
20 bar (290 psi)
Rated Fatigue Pressure
20 bar (290 psi)
Process Fluid Temperature
-40 – 90°C (-40 – 194°F)
Ambient Temperature
-40 – 60°C (-40 – 140°F)
Electrical Connector
8 pin M12 Plug To IEC 61076-2-101
Measurement %RH
0 - 100% RH
Temp. Measurement Range
-25 – 125°C (-13 – 257°F)
Compatibility
The water sensor is not to be used in water based fluids
Ingress Rating Electronics
IP 68 to IEC 60529 when assembled
Physical Dimensions
30 Hex x 73(H)mm
Power Requirement
24V DC