Installation Guide DEVIreg™ Touch Electronic Intelligent Timer Thermostat PLEASE DO NOT TRY TO ASSEMBLE THIS THERMOSTAT BEFORE FULLY READING THROUGH THE INSTRUCTIONS AND UNTIL THE TIME OF INSTALLATION. Please note that disassembly can be challenging and should be avoided to ensure against the damage to any individual part or the thermostat as a whole. www.DEVI.
DEVIreg™ Touch Table of Contents 1 Introduction . . . . . . . . . . . . . . . 1.1 Technical Specifications . . . . . 1.2 Safety Instructions . . . . . . . . 3 4 7 2 Mounting Instructions . . . . . . . . . 8 3 Settings . . . . . . . . . . . . . . . . . 3.1 Initial Settings . . . . . . . . . . 3.2 Forecast . . . . . . . . . . . . . . 3.3 Window Open . . . . . . . . . . 3.4 Maximum Floor Temperature . 12 12 16 18 19 4 Symbols 23 5 Warranty 6 Disposal Instruction 1 Introduction . . . . . . .
DEVIreg™ Touch ▪ An installation wizard with room/floor type-specific setup. ▪ Support for multiple frame systems. ▪ Compatible with several 3rd party NTC sensors. ▪ Thermostat settings can be specified before installation and imported to the thermostat using a web-generated code, or copied from a thermostat in a similar installation. ▪ Smart access to thermostat settings after installation by using a web code interface for easy setup or remote troubleshooting.
DEVIreg™ Touch Sensing units NTC 6.8 kOhm at 25°C NTC 10 kOhm at 25°C NTC 12 kOhm at 25°C NTC 15 kOhm at 25°C (Default) NTC 33 kOhm at 25°C NTC 47 kOhm at 25°C Sensing values: (Default NTC 15 K) 0°C 20°C 50°C 42 kOhm 18 kOhm 6 kOhm Control PWM (Pulse Wide Modulation) Ambient temperature 0° to +30°C Frost protection temperature 5°C to +9°C (default 5°C) Temperature range Room temperature: 5-35°C. Floor temperature: 5-45°C. Max. floor: 20-35°C (if unrecoverable seal is broken then up to 45°C). Min.
DEVIreg™ Touch Sensor failure monitoring The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or shortcircuited Cable specification max.
DEVIreg™ Touch 1.2 Safety Instructions before installation. IMPORTANT: When the thermostat is used to control a to determine suitable temperature settings (it is restrictions. Please also note the following: ▪ The installation of the thermostat must be done by a licensed electrician according to local regulations. ▪ The thermostat must be connected to a power supply via a suitably rated RCD/safety switch. ▪ Always connect the thermostat to continuous power supply.
DEVIreg™ Touch 2 Mounting Instructions Please observe the following placement guidelines: Place the thermostat at a suitable height on the wall (typically 80-170cm.). The thermostat should not be placed in wet rooms. Place it in an adjacent room. Always place the thermostat according to local regulation on IP classes. Do not place the thermostat on the inner side of an exterior wall. Always install the thermostat at least 50 cm. from windows and doors.
DEVIreg™ Touch Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor. ▪ Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings. ▪ Equally distant and >2cm from two heating cables. ▪ The conduit should be flush with the floor surface countersink the conduit if necessary.
DEVIreg™ Touch Follow the steps below to mount the thermostat: 1. Open the thermostat: Important: Do NOT press on the display screen when removing the front part. pull toward you: (bottom piece) until all wiring connections to terminals are complete. The display screen is NOT EASY to remove once it has been pressed into place! 2. Connect the thermostat according to the connection diagram.
DEVIreg™ Touch The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector. Note: Always install the floor sensor in a conduit in the floor. 3. Mount and reassemble the thermostat. ▪ Fasten the thermostat to a wall bracket or wall box by driving the screws through the holes in each side of the thermostat. ▪ Put the frame on.
DEVIreg™ Touch Initially it is recommended to leave the thermostat connected to the main supply for 15 hours to fully charge the battery. The current time and day is then kept for 24 hours if mains supply is off. All other settings are stored permanently. 3 Settings 3.1 Initial Settings Initial settings must be specified when the unit is activated for the first time: 1. 12 Use the arrows on the right side of the screen to go to your language, and press to select it.
DEVIreg™ Touch 2. Press the hour numbers and use the < and > arrows to set the hour. Press to confirm. 3. Press the minutes numbers and use the < and > arrows to set the minutes. Press to confirm. Press again to go to the SET DATE screen. 4. Press the day, month and year respectively and set the date using the < and > arrows and pressing to confirm. When the date is correct, press to confirm. 5. If you have already made the installation setup online, press ENTER CODE and go directly to Step 13 now.
DEVIreg™ Touch 6. On the SETUP information screen, press to start. 7. Use the < and > arrows to select whether only a floor sensor or a combination of room and floor sensors should be used. Press to confirm. Note: A "room only" option may also be available. For details, see the "Maximum Floor Temperature" section. 8. 14 Use the < and > arrows to select the installed floor sensor type. (Measured resistance and corresponding temperature are shown in brackets). Press to confirm.
DEVIreg™ Touch 9. Use the < and > arrows to select the flooring type. Press to confirm. 10. Use the < and > arrows to select the room type. Press to confirm. 11. Use the < and > arrows to select the approximate load of the heating element. If an external relay is used or the installed output is unknown, select the "– –" option. Press to confirm. Use the < arrow to find “_ _” at the low end of this range, or ‘zero’.
DEVIreg™ Touch 12. Use the < and > arrows to select whether the timer should be activated or not. Press to confirm and end the initial thermostat setup. Skip Step 13. 13. Enter your web-generated code. Then press to end the initial thermostat setup. If no check mark ( ) appears, the hexacode is incorrect. 3.2 Forecast The forecast feature is used when you switch between economy temperature and comfort temperature.
DEVIreg™ Touch The forecast feature also optimises heating stop when switching from comfort temperature to economy temperature. How to turn the forecast feature on and off. 1. Touch the thermostat display to activate it, then press menu. 2. Press SETTINGS in the bottom right corner of the menu. Then press OPTIONS.
DEVIreg™ Touch 3. Press FORECAST. Then press ON to optimise heating start/stop or OFF to simply let the heating start/stop at the specified time. Press to confirm. To return to the normal temperature display, press the back arrow in the upper left corner of the screen until you get to the main menu, then press . 3.3 Window Open How to turn "window open detection" on or off 1. Touch the thermostat display to activate it, then press menu. 2. Press SETTINGS in the bottom right corner of the menu.
DEVIreg™ Touch 3. Press WINDOW OPEN. Then press ON to temporarily turn off heating in case of a sudden temperature drop in the room or OFF to let the thermostat heat during sudden temperature drops in the room. Press to confirm. To return to the normal temperature display, press the back arrow in the upper left corner of the screen until you get to the main menu, then press . 3.4 Maximum Floor Temperature How to set the maximum floor temperature 1.
DEVIreg™ Touch 2. Press SETTINGS in the bottom right corner of the menu. Then press INSTALLATION and MANUAL SETUP. 3. Press MAX. FLOOR. Then use the < and > arrows to set the allowed maximum floor temperature. Press to confirm. To return to the normal temperature display, press the back arrow in the upper left corner of the screen until you get to the main menu, then press .
DEVIreg™ Touch If you break the small plastic seal on the back of the display module, e.g. using a screwdriver, it will be possible to set ture up to 45°. Furthermore, it will be possible to use only a room sensor. However, this option is not recommended for use with floor heating due to an increased risk of IMPORTANT: When the thermostat is used to control a to determine suitable temperature settings (it is restrictions.
DEVIreg™ Touch Thermal resistance [m2K/ W] Examples of flooring Details Approximate setting for 25˚C floor temperature 0.05 8 mm HDF based laminate > 800 kg/m3 28˚C 0.10 14 mm beech parquet 650 - 800 kg/m3 31˚C 0.13 22 mm solid oak plank > 800 kg/m3 32˚C < 0.17 0.18 22 Max. carpet thickness acc.
DEVIreg™ Touch 4 Symbols The following symbols may appear in the upper left corner of the temperature display: Symbol What it means The thermostat is in manual mode, i.e. the timer function is off. The timer lets you automatically switch between economy and comfort temperatures according to a predefined schedule. An away period has been planned. On the date of departure, the away period starts at 00:00 and the specified away temperature will be maintained 24 hours a day until the date of return at 00:00.
DEVIreg™ Touch 5 Warranty 5 YEAR 6 24 Disposal Instruction Installation Guide
DEVIreg™ Touch Installation Guide 25
DEVIreg™ Touch 26 Installation Guide
DEVIreg™ Touch Danfoss A/S Electric Heating Systems Ulvehavevej 61 7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 E-mail: EH@DEVI.com www.DEVI.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
5 703466 215135 Designed in Denmark for Danfoss A/S DK EL 7224215603 NO EL 5402666 FI SSTL 2600100 Product Documentation Intelligent Timer Thermostat Floor / Room Sensor 220-240V~ 50-60Hz~ 0 to +30°C 16A/3680W@230V~ IP 21 140F1064 DEVIreg Touch Design Frame Devex Systems specialises in heating, cooling and insulation solutions for new and existing buildings in residential, commercial and industrial environments.