Specifications
RobotShop Inc. Robotics at your service!
Commands
The USB-RLY08 operates with an easy to use command set as described in the table below.
Most commands are only a single byte and if applicable the USB-RLY08 will automatically send
its response. The only exception to this being the "Set relay states" command which requires and
additional desired states byte to be sent immediately after the command byte.
Command
dec hex
Action
90 5A
Get software version -
returns 2 bytes, the first being the
Module ID which is 8, followed by the software version
91 5B
Get relay states - sends a single byte back to the
controller, bit high meaning the corresponding relay is
powered
92 5C
Set relay states - the next single byte will set all relays
states, All on = 255 (11111111) All off = 0
100 64
All relays on
101 65
Turn relay 1 on
102 66
Turn relay 2 on
103 67
Turn relay 3 on
104 68
Turn relay 4 on
105 69
Turn relay 5 on
106 6A
Turn relay 6 on
107 6B
Turn relay 7 on
108 6C
Turn relay 8 on
110 6E
All relays off
111 6F
Turn relay 1 off
112 70
Turn relay 2 off
113 71
Turn relay 3 off
114 72
Turn relay 4 off
115 73
Turn relay 5 off
116 74
Turn relay 6 off
117 75
Turn relay 7 off
118 76
Turn relay 8 off