Documentation
Table Of Contents
Relay power rating
If the contact load voltage and current of the relay are in the region enclosed by the solid and dotted lines in the figure
below, the relay can perform stable switching operation. If the relay is used at a voltage or current exceeding this
region, the life of the contacts may be significantly shortened.
load
type
Typical applications Rating
Max DC load capacity
AC1
Non inductive or
slightly inductive loads
16A @ 250V AC
AC15
Control of
electromagnetic load
(>72VA)
3A @ 120V AC
1.5A @ 240V AC
AC3 Control of motor 750W
DC1
Non inductive or
slightly inductive loads
16A @ 24V DC
DC13
Control of
electromagnetic
loads
0.22A @ 120V DC
0.1A @ 250V DC
A full datasheet for the relays used on the ETH008-B is here: HF115FD datasheet
Power relays
Two 16A volt free contact relays are provided for switching a common input between a normally closed output and a
normally open output. The relay coil is powered by the 12vdc incoming supply on user command.
Coil C
Relay in passive state
NC NO
Coil C
Relay in powered state
NC NO
© Devantech Ltd 06/10/21 ETH008-B Documentation 2/11