Data Sheet

dS2824
dS2824 User Manual v3.01
Erasing old configuration settings
Uploading the firmware, as described in the previous section, will not erase all the
configuration values. If you need to clear these, do the following:
Load up the app-dS2824-v3.01 application in the editor, but before you upload it to the
dS2824 you need to make a small change. Locate the label "main" (click the word in the right
panel is quickest). Just below this is a commented out line "gosub init".
Uncomment this by removing the semicolon.
Now upload the application and it will reset the IP address along with all other variables.
Confirm the board is operating, but don't change anything yet.
You need to replace the semicolon and upload the application again, otherwise it will continue
to reset everything each time you power-up.
Copyright © 2016-2018, Devantech Ltd.
All rights reserved.
www.robot-electronics.co.uk
45