Data Sheet
BNO055
Data sheet
Page 65
BST-BNO055-DS000-14 | Revision 1.4 | June 2016 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on
to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
4.3.41 LIA_DATA_X_LSB 0x28
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Access
r
r
r
r
r
r
r
r
Reset
0
0
0
0
0
0
0
0
Content
Linear Acceleration Data X <7:0>
DATA
bits
Description
Linear
Acceleration Data
X <7:0>
<7:0>
Lower byte of X axis Linear Acceleration data, read only
The output units can be selected using the UNIT_SEL register and data output type can be
changed by updating the Operation Mode in the OPR_MODE register, see section 3.3
4.3.42 LIA_DATA_X_MSB 0x29
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Access
r
r
r
r
r
r
r
r
Reset
0
0
0
0
0
0
0
0
Content
Linear Acceleration Data X <15:8>
DATA
bits
Description
Linear
Acceleration Data
X <15:8>
<7:0>
Upper byte of X axis Linear Acceleration data, read only
The output units can be selected using the UNIT_SEL register and data output type can be
changed by updating the Operation Mode in the OPR_MODE register, see section 3.3
4.3.43 LIA_DATA_Y_LSB 0x2A
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Access
r
r
r
r
r
r
r
r
Reset
0
0
0
0
0
0
0
0
Content
Linear Acceleration Data Y <7:0>
DATA
bits
Description
Linear
Acceleration Data
Y <7:0>
<7:0>
Lower byte of Y axis Linear Acceleration data, read only
The output units can be selected using the UNIT_SEL register and data output type can be
changed by updating the Operation Mode in the OPR_MODE register, see section 3.3
4.3.44 LIA_DATA_Y_MSB 0x2B
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Access
r
r
r
r
r
r
r
r
Reset
0
0
0
0
0
0
0
0
Content
Linear Acceleration Data Y <15:8>
DATA
bits
Description
Linear
Acceleration Data
Y <15:8>
<7:0>
Upper byte of Y axis Linear Acceleration data, read only
The output units can be selected using the UNIT_SEL register and data output type can be
changed by updating the Operation Mode in the OPR_MODE register, see section 3.3