Specifications
Servicing and maintenance works Aspiration system
40 © 2008
6
Maintenance indicators for dry air filter
z
The dry air filter is maintained according to a
maintenance switch or maintenance indicator.
z
Maintenance is necessary when:
– the yellow warning light of the
maintenance
switch
lights up when the engine is running.
– the red field (1) of the
maintenance indica-
tor
is fully visible.
z
After carrying out maintenance work, reset the
signal by pressing the button on the mainte-
nance indicator. The maintenance indicator is
now ready for operation again.
Emptying the cyclone precleaner
z
Loosen wing nut (1) and lift off housing cover (2).
z
Remove the dust container (3) from the base (4)
and empty it. Clean the container using a brush
and clean diesel fuel. Then dry.
z
Place the dust container (3) on the base (4) and
tighten the housing cover (2) with wing nut (1).
Never fill the dust container (3) with lubri-
cating oil!
Cleaning oil bath air filter
z
Shut down engine and wait about 10 minutes un-
til the lubricating oil has collected in the lubricat-
ing oil pan (3).
z
Loosen the quick release clamps (2) and remove
the lubricating oil pan (3) with filter insert (4).
z
Collect draining lubricating oil
z
Dispose of in an environmentally correct man-
ner.
z
Clean lubricating oil pan (3), filter cartridge (4)
and filter housing (1) with a brush and clean die-
Never clean the filter with petrol!
Dispose of the old lubricating oil in accord-
ance with the regulations. Select the en-
gine lubricating oil according to the
requirements before filling the filter.
OBJ_DOKU-16314-001.fm Seite 40 Donnerstag, 24. Juli 2008 11:18 11