Instruction Manual

Section 3 - Controls and Indicators
3-14 31200537
Load Stability Indicator (LSI)
Before S/N 1160005993 excluding 1160005949 & 1160005950
The LSI (1) provides visual and audible indication of forward stability limitations
when machine is static on firm, level surface.
Green LED (2) will illuminate when LSI power is on.
When approaching forward stability limitations LEDs progressively illuminate,
green (3), then yellow (4) and finally red (5).
The warning buzzer sounds as the first red LED illuminates.
As the telehandler reaches forward stability limitations and the second red LED
illuminates, the automatic function cut-out is activated. Certain functions are
disabled (i.e. boom lift, extend, etc). Retract boom to re-enable functions.
Press button (6) to disable the warning buzzer. When disabled, yellow LED (7)
will illuminate. If last red LED illuminates, disable button is overridden and
warning buzzer sounds.
Test LSI (8) at the beginning of each work shift. See Section 8 - Additional
Checks.
WARNING
TIP OVER HAZARD. The LSI considers only longitudinal stability limitations,
observe all operating parameters. Failure to follow operating parameters of the
telehandler could damage the equipment and/or cause tip over.
OZ2340