Manual

Section 3 - Controls and Indicators
3-14 31200570
Load Stability Indicator - LSI
Before S/N 1160005989 excluding 1160005189, 1160005314 & 1160005414
The LSI (1) provides visual and audible indication of forward stability limitations
when machine is static on firm, level surface.
Green LED (2) will illuminate when LSI power is on.
When approaching forward stability limitations LEDs progressively illuminate,
green (3), then yellow (4) and finally red (5).
The warning buzzer sounds as the yellow LED illuminates.
As the telehandler reaches forward stability limitations and the red LED
illuminates, the automatic function cut-out is activated. Certain functions are
disabled (i.e. boom lift, extend, etc). Retract boom to re-enable functions.
Test LSI (6) at the beginning of each work shift. See Section 8 - Additional
Checks.
WARNING
TIP OVER HAZARD. The LSI considers only longitudinal stability limitations,
observe all operating parameters. Failure to follow operating parameters of the
telehandler could damage the equipment and/or cause tip over.
OAH1330
1
2
3
4
5
6
Load Moment
Indicator
100%
TEST