Workshop Manual

© 06/2006 8247-001
1/2
TCD 2015
Electrical system
W 13-08-01
6
Removing and installing the pressure/temperature sensor
(charge air)
Commercial available tools
Fitting compound
DEUTZ AP1908
Read out error memory of the motor con-
trol timer with SERDIA.
Remove pressure/temperature sensor
z Unlock cable plug (1) and remove.
1
© 40919-0
z Unscrew screw (1).
z Remove pressure/temperature sensor
z Visually inspect the components.
1
© 40946-0