Workshop Manual

© 06/2006 8236-001
1/2
TCD 2015
Cooling system
W 09-08-01
6
Checking the thermostat when uninstalled
Commercial available tools:
Thermometer
W 09-08-02
Danger!
Risk of injury!
Hot water and hot thermostat.
Checking thermostat
z Remove thermostats.
W 09-08-02
z Measure beginning of stroke, dimension (a).
z Note measured value, dimension (a).
© 34679-3
z Heat up the thermostat in the water bath.
z Determine beginning of opening.
P09 11
P09 12
In order to determine the exact beginning
of opening, the temperature should be
measured as close as possible to the ther-
mostat.
Do not touch the thermostat.
The water should be continuously stirred
for an even temperature distribution. The
temperature rise should not take place
faster than 1°C/min. Otherwise the begin-
ning of opening will be delayed accordin-
gly.
© 34680-2