Workshop Manual

© 06/2006 8152-001
1/6
TCD 2015
Cylinder head
W 01-02-06
6
Disassembling, assembling and checking the rocker arm and rocker arm
bracket
Commercial available tools:
Internal measuring device
Micrometer gauge
Special tools:
Dial gauge. . . . . . . . . . . . . . . . . . 100400
Disassembly/assembly
tool . . . . . . . . . . . . . . . . . . . . . . . 170120
W 01-02-02
Disassembling the rocker arm bracket
z Remove rocker arm and rocker arm bracket.
W 01-02-02
© 34824-2
Checking rocker arm (inlet valves)
z Prepare internal measuring device:
Mount probe bolt for the appropriate measuring
range in the internal measuring device.
Mount dial gauge with approx. 1 mm pre-tension in
the internal measuring device.
Set micrometer gauge to 28 mm.
Balance the internal measuring device between
the test surfaces of the micrometer gauge and set
the dial gauge to the reversal point of the pointer to
"0".
© 34768-2