Workshop Manual
© 06/2006 8211-001
1/6
TCD 2015 Railway
Fuel system
W 07-01-03
6
Removing and installing fuel shut-off valve
(flame glow plugs)
Commercial available tools
Special tools:
– Plugs/caps . . . . . . . . . . . . . . . . . 170160
Attention!
Pay attention to utmost cleanliness when
working on the fuel system.
Remove residue paint and particles of dirt
before removing.
Clean the respective affected parts care-
fully. Blow damp areas dry with compres-
sed air.
Observe the safety regulations and natio-
nal specifications for handling fuels.
Close all connections immediately after
opening with new, clean plugs/caps.
Do not remove plugs/caps until immedia-
tely before assembling.
Collect leaking operating substances in
suitable vessels and dispose of according
to regulations.
Removing fuel shut-off valve
z Unlock cable plug (1) and remove.
1
© 42020-2