Workshop Manual
© 06/2006 8183-001
1/8
TCD 2015
Crankcase
W 03-11-01
6
Removing and installing, testing camshaft bearing
Commercial available tools:
– Micrometer gauge
– Internal measuring device
Special tools:
– Dial gauge. . . . . . . . . . . . . . . . . . 100400
– Assembly tool . . . . . . . . . . . . . . . 143830
– W 04-05-05
Testing camshaft bearing
z Remove camshaft.
W 04-05-05
© 42126-1
z Prepare internal measuring device:
– Mount probe bolt for the appropriate measuring
range in the internal measuring device.
– Mount dial gauge with approx. 1 mm pre-tension in
the internal measuring device.
– Set micrometer gauge to 70 mm.
– Balance the internal measuring device between
the test surfaces of the micrometer gauge and set
the meter at the reversal point of the pointer to "0".
© 34768-2