Workshop Manual

© 06/2006 8183-001
1/8
TCD 2015
Crankcase
W 03-11-01
6
Removing and installing, testing camshaft bearing
Commercial available tools:
Micrometer gauge
Internal measuring device
Special tools:
Dial gauge. . . . . . . . . . . . . . . . . . 100400
Assembly tool . . . . . . . . . . . . . . . 143830
W 04-05-05
Testing camshaft bearing
z Remove camshaft.
W 04-05-05
© 42126-1
z Prepare internal measuring device:
Mount probe bolt for the appropriate measuring
range in the internal measuring device.
Mount dial gauge with approx. 1 mm pre-tension in
the internal measuring device.
Set micrometer gauge to 70 mm.
Balance the internal measuring device between
the test surfaces of the micrometer gauge and set
the meter at the reversal point of the pointer to "0".
© 34768-2