Workshop Manual
TCD 2015
Drive system
W 02-03-01
© 06/2006 8167-001
6/10
6
z Tighten screws .
A02 020
© 34778-2
z Prepare internal measuring device:
– Mount probe bolt for the appropriate measuring
range in the internal measuring device.
– Mount dial gauge with approx. 1 mm pre-tension in
the internal measuring device.
– Set micrometer gauge to 91 mm.
– Balance the internal measuring device between
the test surfaces of the micrometer gauge and set
the meter at the reversal point of the pointer to "0".
© 36094-1
Diagram for measuring the inside diameter
of the con rod bearing shells at the
points "a" and "b" in the levels "1" and "2".
© 37239-1