Workshop Manual

TCD 2015
Drive system
W 02-03-01
© 06/2006 8167-001
6/10
6
z Tighten screws .
A02 020
© 34778-2
z Prepare internal measuring device:
Mount probe bolt for the appropriate measuring
range in the internal measuring device.
Mount dial gauge with approx. 1 mm pre-tension in
the internal measuring device.
Set micrometer gauge to 91 mm.
Balance the internal measuring device between
the test surfaces of the micrometer gauge and set
the meter at the reversal point of the pointer to "0".
© 36094-1
Diagram for measuring the inside diameter
of the con rod bearing shells at the
points "a" and "b" in the levels "1" and "2".
© 37239-1