Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21820-001.fm
6/6
6
Connection housing
TCD 2013 2VW 52-01-02
Measurement sheet - connection housing / radial run-out limit value
SAE 4 361,95 0,25
SAE 5 314,32 0,25
Issued by:
Date:
Engine number:
Connection housing:
Position
(I) (II) (III) (IV)
1 Display on dial gauge 100410 0 a = b = c =
1a Arithmetic value (reversal of the sign) a1 = b1 = c1 =
2
Correction radial bearing clearance (d)
(d) = 0.06 mm
--d = -
3
Half of the bearing clearance correction
(d/2)
- d/2 = - d/2 =
4
Corrected vertical total dial gauge
display (L
v
)
L
v
=
5
Corrected horizontal dial gauge display
(E1, E2)
-
E
1
=
-
E
2
=
6
Horizontal total dial gauge display (L
H
)L
H
=
Calculation
L
v
=b1+d L
v
=
E
1
=a1+d/2 E
1
=
E
2
=c1+d/2 E
2
=
L
H
=E
1
-E
2
L
H
=
L
R
=
L
R
= determined radial run-out limit value (t)
t=
Connection housing
SAE size
(t) Radial run-out limit value
(mm)
Radial run-out alignment in
order
New alignment necessary
Nominal Actual
SAE 0 0,45
SAE 1 0,36
SAE 2 0,31
SAE 3 0,29
SAE 4 0,25
SAE 5 0,25