Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21820-001.fm
3/6
6
Connection housing
TCD 2013 2V W 52-01-02
Turn the crankshaft slowly to position (III).
Read off measured value.
Note measured value, dimension (b).
Note the measured value (b) with the appropriate
sign on the measurement sheet.
Position (III)
Note the sign!
III
© 47691-0
Turn the crankshaft slowly to position (IV).
Read off measured value.
Note the measured value, dimension (c).
Note the measured value (c) with the appropriate
sign on the measurement sheet.
Position (IV)
Note the sign!
IV
© 47692-0
Turn the crankshaft slowly to position (I).
The dial gauge must indicate measured value "0"
again.
Make the calculation according to the example in ta
-
ble 1.
In case of a radial run-out deviation above
the specified run-out limit value, the con
-
nection housing must be disconnected.
I
© 47688-0