Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21820-001.fm
1/6
6
Connection housing
TCD 2013 2V W 52-01-02
Check alignment of connection housing
8190
Standard tools:
Magnetic measuring stand
Self-made mandrin guide
Special tools:
Digital dial gauge 100410
Attention!
Prerequisites:
Radial bearing clearance and axial
clearance of the crankshaft in the permis
-
sible tolerance range.
Test surfaces must be dry and free from
dirt and burr!
Checking the rotation
Mount the engine on the assembly block.
Make help marks at a distance of 90° on the connec
-
tion housing.
Position (I)
Position (II)
Position (III)
Position (IV)
I
III
II
VI
© 47687-0
Screw the self-made guide pin (1) tight.
Mount the measuring stand (2) on the guide pin.
Insert dial gauge in dial gauge holder.
1
2
© 47686-0