Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21811-001.fm
4/6
6
Electrical equipment
TCD 2013 2VW 48-02-01
Press the impulse transmitter lightly against the feel
-
er gauge blade.
Tighten screws (arrows).
20 Nm
© 44093-0
Check gap dimension with feeler gauge blade.
0,6 mm
The feeler gauge blade must fit between
the tooth lock washer and impulse trans
-
mitter (crankshaft) with low resistance.
© 44094-0
+0.1
- 0.1
Lay cable between front cover and coolant pump (ar
-
row).
© 44095-0